The aim of the described experimentation was the comparison of a low cost MBBR and an activated sludge system (AS). The MBBR applied system consists of the FLOCOR-RM(R) plastic media with a specific surface area of about 160 m(2)/m(3) (internal surface only). The comparison with activated sludge (AS) was performed by two parallel treatment lines. Organic substance removal and nitrification were investigated over a 1-year period. Comparing the results obtained with the two lines, it can be observed AS totCOD removal efficiencies were higher than MBBR ones; the average efficiencies for totCOD removal were 76% for MBBR and 84% for AS. On the contrary, the solCOD removals resulted alike (71% for both systems). In spite of the remarkable variations of wastewater temperature, mainly in winter (range of 5-21 degrees C), the average ammonium removal efficiency resulted 92% for MBBR and 98% for AS. With an ammonium loads up to 1.0 g m(-2) d(-1) (up to 0.12 kg m(-3) d(-1)), nitrification efficiencies in MBBR were more than 98%. At higher loads decrease in the MBBR efficiency was registered; that is related to the increase in the applied COD load.
Experimental comparison between MBBR and activated sludge system for the treatment of municipal wastewater
TATANO, FABIO
2000
Abstract
The aim of the described experimentation was the comparison of a low cost MBBR and an activated sludge system (AS). The MBBR applied system consists of the FLOCOR-RM(R) plastic media with a specific surface area of about 160 m(2)/m(3) (internal surface only). The comparison with activated sludge (AS) was performed by two parallel treatment lines. Organic substance removal and nitrification were investigated over a 1-year period. Comparing the results obtained with the two lines, it can be observed AS totCOD removal efficiencies were higher than MBBR ones; the average efficiencies for totCOD removal were 76% for MBBR and 84% for AS. On the contrary, the solCOD removals resulted alike (71% for both systems). In spite of the remarkable variations of wastewater temperature, mainly in winter (range of 5-21 degrees C), the average ammonium removal efficiency resulted 92% for MBBR and 98% for AS. With an ammonium loads up to 1.0 g m(-2) d(-1) (up to 0.12 kg m(-3) d(-1)), nitrification efficiencies in MBBR were more than 98%. At higher loads decrease in the MBBR efficiency was registered; that is related to the increase in the applied COD load.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.