We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single-gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistance R of the two RPC prototypes over three years: we observe a large spontaneous increase of R with time, from the initial value of about 2 MOmega to more than 250 MOmega. A corresponding degradation of the RPC rate capabilities, from more than 3 kHz/cm(2) to less than 0.15 kHz/cm(2) is also found.
New results from an extensive aging test on bakelite resistive plate chambers
VELTRI, MICHELE
2003
Abstract
We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single-gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC under high particle flux conditions, we have periodically measured the electrode resistance R of the two RPC prototypes over three years: we observe a large spontaneous increase of R with time, from the initial value of about 2 MOmega to more than 250 MOmega. A corresponding degradation of the RPC rate capabilities, from more than 3 kHz/cm(2) to less than 0.15 kHz/cm(2) is also found.File in questo prodotto:
Non ci sono file associati a questo prodotto.