Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
A combination of three LHCb measurements of the CKM angle gamma is presented. The decays B-+/- -> DK +/- and B-+/- -> D pi(+/-) are used, where D denotes an admixture of D-0 and (D) over bar (0) mesons, decaying into K+K-, pi(+)pi(-), K-+/-pi(-/+), K-+/-pi(-/+)pi(+/-)pi(-/+), or K-S(0)pi(+)pi(-) final states. All measurements use a dataset corresponding to 1.0 fb-1 of integrated luminosity. Combining results from B-+/- -> DK +/- Dill decays alone a best-fit value of gamma = 72.0 degrees is found, and confidence intervals are set gamma is an element of [56.4, 86.7]degrees at 68% CL, gamma is an element of [42.6, 99.6]degrees at 95% CL. The best-fit value of gamma found from a combination of results from B-+/- -> D pi(+/-) decays alone, is gamma = 18.9 degrees, and the confidence intervals gamma is an element of [7.4, 99.2]degrees boolean OR [167.9, 176.4]degrees at 68% CL are set, without constraint at 95% CL The combination of results from B1 DKI and B -> DTC decays gives a best-fit value of y = 72.6 degrees and the confidence intervals gamma is an element of [55.4, 82.3]degrees at 68% CL, gamma is an element of [40.2, 92.7]degrees at 95% CL are set. All values are expressed modulo 180 degrees, and are obtained taking into account the effect of D-0-(D) over bar (0) mixing.
Measurement of the CKM angle gamma from a combination of B-+/- -> Dh(+/-) analyses
A combination of three LHCb measurements of the CKM angle gamma is presented. The decays B-+/- -> DK +/- and B-+/- -> D pi(+/-) are used, where D denotes an admixture of D-0 and (D) over bar (0) mesons, decaying into K+K-, pi(+)pi(-), K-+/-pi(-/+), K-+/-pi(-/+)pi(+/-)pi(-/+), or K-S(0)pi(+)pi(-) final states. All measurements use a dataset corresponding to 1.0 fb-1 of integrated luminosity. Combining results from B-+/- -> DK +/- Dill decays alone a best-fit value of gamma = 72.0 degrees is found, and confidence intervals are set gamma is an element of [56.4, 86.7]degrees at 68% CL, gamma is an element of [42.6, 99.6]degrees at 95% CL. The best-fit value of gamma found from a combination of results from B-+/- -> D pi(+/-) decays alone, is gamma = 18.9 degrees, and the confidence intervals gamma is an element of [7.4, 99.2]degrees boolean OR [167.9, 176.4]degrees at 68% CL are set, without constraint at 95% CL The combination of results from B1 DKI and B -> DTC decays gives a best-fit value of y = 72.6 degrees and the confidence intervals gamma is an element of [55.4, 82.3]degrees at 68% CL, gamma is an element of [40.2, 92.7]degrees at 95% CL are set. All values are expressed modulo 180 degrees, and are obtained taking into account the effect of D-0-(D) over bar (0) mixing.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11576/2639072
Citazioni
ND
56
49
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.