Solid-phase microextraction (SPME) directly coupled to MS is a widespread technique for determining small molecules in different matrices in many application fields. Here we present a modified microfluidic open interface (MOI) connected to a passive-flow-splitter device (PFS) for the direct coupling of SPME to a liquid-electron ionization (LEI) interface in a tandem mass spectrometer for the analysis of complex biological samples. No chromatographic separation is involved. The new MOI-PFS configuration was designed to speed up the sample transfer to MS, improving the signal-to-noise ratio and peak shape and leading to fast and sensitive results. MOI-PFS-LEI-MS/MS experiments were conducted using fentanyl as a model compound in water and blood serum. The method uses a C18 Bio-SPME fiber by direct immersion (3 min) in 300 μL of the sample followed by rapid desorption (1 min) in a flow isolated volume (MOI chamber, 2.5 μL) filled with 100% acetonitrile. The PFS permits the rapid transfer of a fraction of the sample into the MS via the LEI interface. The optimal conditions were obtained at a flow rate of 10 μL•min−1 and a 1:20 split ratio. Altogether, extraction, desorption, and analysis require approximately 5 min. Good interday and intraday precision, excellent linearity and LOQs in the μg•L−1 range were obtained for fentanyl in water and serum. Greenness evaluation demonstrated a limited environmental impact of this technique.
Enhanced Microfluidic Open Interface for the Direct Coupling of Solid Phase Microextraction with Liquid Electron Ionization-Tandem Mass Spectrometry
Nicole Marittimo;Giorgio Famiglini;Pierangela Palma;Adriana Arigo;Achille Cappiello
2022
Abstract
Solid-phase microextraction (SPME) directly coupled to MS is a widespread technique for determining small molecules in different matrices in many application fields. Here we present a modified microfluidic open interface (MOI) connected to a passive-flow-splitter device (PFS) for the direct coupling of SPME to a liquid-electron ionization (LEI) interface in a tandem mass spectrometer for the analysis of complex biological samples. No chromatographic separation is involved. The new MOI-PFS configuration was designed to speed up the sample transfer to MS, improving the signal-to-noise ratio and peak shape and leading to fast and sensitive results. MOI-PFS-LEI-MS/MS experiments were conducted using fentanyl as a model compound in water and blood serum. The method uses a C18 Bio-SPME fiber by direct immersion (3 min) in 300 μL of the sample followed by rapid desorption (1 min) in a flow isolated volume (MOI chamber, 2.5 μL) filled with 100% acetonitrile. The PFS permits the rapid transfer of a fraction of the sample into the MS via the LEI interface. The optimal conditions were obtained at a flow rate of 10 μL•min−1 and a 1:20 split ratio. Altogether, extraction, desorption, and analysis require approximately 5 min. Good interday and intraday precision, excellent linearity and LOQs in the μg•L−1 range were obtained for fentanyl in water and serum. Greenness evaluation demonstrated a limited environmental impact of this technique.File | Dimensione | Formato | |
---|---|---|---|
p74(2022).pdf
solo utenti autorizzati
Tipologia:
Versione editoriale
Licenza:
Copyright dell'editore
Dimensione
1.44 MB
Formato
Adobe PDF
|
1.44 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
revised manuscript (1).docx
accesso aperto
Tipologia:
Versione pre-print
Licenza:
Creative commons
Dimensione
55.25 kB
Formato
Microsoft Word XML
|
55.25 kB | Microsoft Word XML | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.