The tetranuclear Cu2+ /Ca2+ /Ca2+ /Cu2+ complex based on Malten ligand has been investigated as a platform for anion binding. Simple organic carboxylates and non-steroidal anti-inflammatory drugs (NSAIDs) have been tested, revealing the ability of the platform to bind them. The receiving platform hosts at least two guests in solution although a third anion can be bound, as suggested by X-ray diffraction analysis. The addition of the anions is accompanied by a color change of the solution, making the system a colorimetric sensor for carboxylates (LOD values comprised between 3.6 and 20.7 ppm). A fluorescent system consisting of the 2-(3-oxido-6-oxoxanthen-9-yl)benzoate (fluorescein anion) linked to the tetranuclear platform has been also prepared and used in a chemosensing ensemble approach to signal the presence of the selected anions (Log K between 2.6 and 5.6 for the addition of two guests). The latter also works in a paper strip test, offering the chemosensor a possible practical application.

A Tetranuclear Copper(II)/Calcium(II) Complex as Dual Chemosensor for Colorimetric and Fluorescent Detection of Non-Steroidal Anti-Inflammatory Drugs

Macedi, Eleonora
;
Giorgi, Luca;Formica, Mauro;Paderni, Daniele;Paoli, Paola;Fusi, Vieri
2023

Abstract

The tetranuclear Cu2+ /Ca2+ /Ca2+ /Cu2+ complex based on Malten ligand has been investigated as a platform for anion binding. Simple organic carboxylates and non-steroidal anti-inflammatory drugs (NSAIDs) have been tested, revealing the ability of the platform to bind them. The receiving platform hosts at least two guests in solution although a third anion can be bound, as suggested by X-ray diffraction analysis. The addition of the anions is accompanied by a color change of the solution, making the system a colorimetric sensor for carboxylates (LOD values comprised between 3.6 and 20.7 ppm). A fluorescent system consisting of the 2-(3-oxido-6-oxoxanthen-9-yl)benzoate (fluorescein anion) linked to the tetranuclear platform has been also prepared and used in a chemosensing ensemble approach to signal the presence of the selected anions (Log K between 2.6 and 5.6 for the addition of two guests). The latter also works in a paper strip test, offering the chemosensor a possible practical application.
File in questo prodotto:
File Dimensione Formato  
N_86_ChemPlusChem_2023.pdf

accesso aperto

Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 1.25 MB
Formato Adobe PDF
1.25 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11576/2710753
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact